Post-Construction Remediation San Jose, CA • December 2025 (2 Business Days)

Post-Remodel Silica & Drywall Dust: 3-Stage HEPA Decontamination

A gut kitchen and master bathroom renovation left fine respirable crystalline silica (RCS) and gypsum dust coating 3,200 sq ft of living space through an unsealed HVAC return duct.

Triage Similar Situation
INITIAL SITE AUDIT (PRE-CLEAN) CONTAMINATED
Airborne Particulate PM2.5 340 ug/m3 (Hazardous)
HVAC Duct Settled Dust 0.25-inch Gypsum Layer
Silica Airborne Exposure > 50 ug/m3 (OSHA PEL Exceeded)
Hardwood Floor Scratches Active Abrasion Risk
→
CLEARANCE PROTOCOL
POST-REMEDIATION (CLEARANCE) PASS / SANITARY
Airborne Particulate PM2.5 8 ug/m3 (Clean Air Standard)
HVAC Duct Cleanliness NADCA Standard Certified
Substrate Dust Wipe Zero White-Glove Residue
Wood Floor Finish Zero Micro-Scratches (Protected)

Containment & Equipment Deployed

  • • 2x Commercial Air Scrubbers (Dri-Eaz DefendAir HEPA 500 CFM)
  • • Class L/M/H Certified HEPA Vacuums with soft horsehair attachments
  • • Laser Particulate Meter (TSI DustTrak Airborne Particle Counter)
  • • High-reach electrostatic microfiber damp poles

Chemical Formulations & Dwell Protocol

  • • Deionized water + antistatic surfactant damp wipe solution
  • • pH 7.0 neutral rinse for finished pre-finished hardwood
  • • Citrus-based natural adhesive remover for fixture tape residue

Itemized Financial Audit & Settlement

Total Project Invoiced: $2,650.00
Insurance Coverage Payout: $2,650.00 (General Contractor CGL Claim)
Client Net Out-of-Pocket / Deductible: $0.00 to Homeowner
Policy Settlement: General Contractor Commercial General Liability

Primary Engineering Takeaway

"Never dry sweep drywall or silica dust. RCS particulates stay suspended in household air for over 12 days and cause permanent lung fibrosis."

The Underlying Challenge

A general contractor completed a $180,000 renovation but failed to isolate the HVAC return registers. When the HVAC fired up, 20 lbs of crystalline silica and sheetrock dust were blown into every furnished bedroom, upholstery, and wardrobe.

The Scientific Remediation Protocol

Technicians established negative air containment and deployed 1,000 CFM of continuous HEPA air filtration. Dry sweeping was strictly banned under OSHA 29 CFR 1926.1153. A 3-stage protocol was executed: (1) Top-down HEPA vacuuming with soft-bristle brushes, (2) Electrostatic damp micro-wiping with deionized surfactant, and (3) Air scrubbing for 24 hours post-wiping.

Quantitative Verification & Clearance Result

Laser particulate monitoring confirmed PM2.5 air levels plummeted from 340 ug/m3 to 8 ug/m3 (clean mountain air quality). The GC's liability insurer reimbursed 100% of the decontamination invoice directly.